Posted on Leave a comment

Mobility status and bone density in cerebral palsy.

date: 08/01/1996
author: Wilmshurst S, Ward K, Adams JE, Langton CM, Mughal MZ.
publication: Arch Dis Child. 1996 Aug;75(2):164-5.
pubmed_ID: 8869203

The spinal bone mineral density (SBMD) and calcaneal broadband ultrasound attenuation (BUA) was measured in 27 children with cerebral palsy. They were categorised into four mobility groups: mobile with an abnormal gait, mobile with assistance, non-mobile but weight bearing, non-mobile or weight bearing. Mean SD scores for BUA and SBMD differed among mobility groups (analysis of variance, p < 0.001 and p = 0.078, respectively).

Posted on Leave a comment

The vertical wheeler: a device for ambulation in cerebral palsy.

date: 10/01/1985
author: Manley MT, Gurtowski J.
publication: Arch Phys Med Rehabilitation. 1985 Oct;66(10):717-20.
pubmed_ID: 4051716
Outside_URL: http://www.ncbi.nlm.nih.gov/pubmed/4051716
The vertical wheeler is a new mobility aid that was specifically designed to help improve the quality of life for the handicapped child by providing mobility while standing. Results of a clinical trial in a population of patients with cerebral palsy are presented. Criteria were selected to allow evaluation of the rehabilitative effect of the device on the population. Results showed that the children in this cerebral palsy group all benefited from ambulation with the wheeler. Patients with spastic quadriparesis seemed to gain the most immediate benefit. The device contributed to improved mobility, posture, and self-image. The wheeler was safe and fun for the children. It has the potential for improving the psychologic and medical status of the child with severe locomotion impairment.

Posted on Leave a comment

Effects of a dynamic versus a static prone stander on bone material density and behavior in four children with severe cerebral palsy.

date: 03/01/2002
author: Gudjonsdottir, Bjorg MS/PT, Vicki Stemmons Mercer, PhD, PT
publication: Pediatric Physical Therapy 2002;14:38-46.
pubmed_ID: 17053680

PURPOSE: in this case series, we examined how two types of prone standers affected bone material density and behavioral variables in four children of preschool age with severe cerebral palsy. METHODS: In phase one, four children of preschool age participated in an eight-week standing program, standing for 30 minutes a day, five days a week. Two children stood in a conventional stander, and two stood in a new type of motorized (dynamic) stander that provides intermittent weight bearing. Measurements of bone material density before and after the program revealed increases in bone material density in both children who used a dynamic stander and one child who used a static stander. In phase two, all four subjects stood in both types of stander during three separate test sessions. RESULT: Measures of behavioral variables, including behavioral state, reactivity, goal directedness, and attention span, indicated little or no effect of type of stander on behavior. CONCLUSIONS: These results suggest there is potential value in additional research concerning the effects of static and dynamic standers on bone material density and behavior in children with cerebral palsy.

Posted on Leave a comment

Technical note–a patient propelled variable-inclination prone stander.

date: 12/01/1983
author: Motloch WM, Brearley MN.
publication: Prosthet Orthot Int. 1983 Dec;7(3):176-7.
pubmed_ID: 6647014

A self-propelled mobile standing device is described with the facility of patient-operated inclination of the support platform, enabling objects on the floor to be reached. The device is provided with a removable tray at the level of the occupant’s chest.

Posted on Leave a comment

Evaluation of the effects of muscle stretch and weight load in patients with spastic paraplegia.

date: 01/01/1981
author: Odeen I, Knutsson E.
publication: Scand J Rehabilitation Medicine. 1981;13(4):117-21.
pubmed_ID: 7347432
Clinical observations on patients with spastic paraplegia have indicated that a training regime including weight load on the lower limbs may reduce the muscular hypertonus. Due to the spontaneous fluctuations and great variability in muscle tone it is difficult to judge from clinical findings how the effects may be related to muscle stretch and weight load. Therefore, quantitative determination of the effects on muscle tone by stretch and loading was made in 9 paraplegic patients. Muscle tone was measured before and after 30 min of stretch or weight load in 8 sessions on 4 consecutive days. Stretch was obtained by bracing the foot in maximal dorsal flexion with patient in supine position. For weight load on the lower limbs, the patient stood on a tilt-table at an angle of 85 degrees with feet in 15 degrees dorsal or plantar flexion. Resistance to passive movements was determined during a series of sinusoidal ankle joint movements at three different speeds. After weight load in standing with the feet in dorsal or plantar flexion, the average reduction was 32 and 26%, respectively. After stretch in supine, the average reduction was 17%. Thus, the three procedures tested all resulted in reduction of muscle tone. The largest reductions were obtained by weight load with stretch imposed upon the calf muscles.

Posted on Leave a comment

Nonoperative treatment of osteogenesis imperfecta: orthotic and mobility management.

date: 09/01/1981
author: Bleck EE.
publication: Clin Orthop Relat Res. 1981 Sep;(159):111-22.
pubmed_ID: 7285447

The problem of osteoporosis superimposed on the basic collagen defect of osteogenesis imperfecta has been approached by the use of plastic containment orthoses for the lower limbs, in addition to developmentally staged mobility devices that assist early standing and walking. The purpose of forcing early weight-bearing is to provide stress to the lower limb bones in order to minimize osteoporosis, prevent refracture and deformity, and curb subsequent immobilization osteoporosis, thus breaking a vicious cycle. Management goals are based upon adult needs for independence: efficiency in daily living activities and in mobility. These goals were reached in most of our patients via use of plastic orthoses, early weight-bearing, and electrically powered wheelchairs. Manual osteoclasis of the tibia followed by plastic orthoses utilizing principles of fluid compression to support fractured or structurally weak bones appeared successful at the time of follow-up. Intramedullary rodding of the femur was necessary in most of the 12 children with osteogenesis imperfecta congenita. Supplementary plastic orthoses have reduced the refracture rate in both the tibia and the femur. Social integration of the children was reflected by the fact that among the 12 OI congenita cases, ten were attending regular educational institutions. Twelve OI tarda children fared well, all attaining complete independence in daily living, mobility and ambulation. Seven of this group were treated with intramedullary rodding of the femur or tibia and with plastic orthoses. Five patients required no treatment.

Posted on Leave a comment

Case study to evaluate a standing table for managing constipation.

date: 06/01/2001
author: Hoenig H, Murphy T, Galbraith J, Zolkewitz M.
publication: SCI Nurse 2001 Summer;18(2):74-7.
pubmed_ID: 12035465

Standing devices have been advocated as a potentially beneficial treatment for constipation in persons with spinal cord injury (SCI); however, definitive data are lacking. A case of a patient who requested a standing table to treat chronic constipation is presented as an illustration of a method to address this problem on an individual patient level. The patient was a 62-year-old male with T12-L1 ASIA B paraplegia who was injured in 1965. The patient was on chronic narcotics for severe, nonoperable shoulder pain. His bowel program had been inadequate to prevent impactions. A systematic approach was used to measure the effects of a standing table on frequency of bowel movements (BMs) and on length of bowel care episodes. There was a significant (p < 0.05) increase in frequency of BMs and a decrease in bowel care time with the use of the standing table 5 times/week versus baseline. For this patient, the use of the standing table was a clinically useful addition to his bowel care program.

Posted on Leave a comment

Use of prolonged standing for individuals with spinal cord injuries.

date: 08/01/2001
author: Eng JJ, Levins SM, Townson AF, Mah-Jones D, Bremner J, Huston G.
publication: Phys Ther. 2001 Aug;81(8):1392-9.
pubmed_ID: 11509069

BACKGROUND AND PURPOSE: Prolonged standing in people with spinal cord injuries (SCIs) has the potential to affect a number of health-related areas such as reflex activity, joint range of motion, or well-being. The purpose of this study was to document the patterns of use of prolonged standing and their perceived effects in subjects with SCIs. SUBJECTS: The subjects were 152 adults with SCIs (103 male, 49 female; mean age=34 years, SD=8, range=18-55) who returned mailed survey questionnaires. METHODS: A 17-item self-report survey questionnaire was sent to the 463 members of a provincial spinal cord support organization. RESULTS: Survey responses for 26 of the 152 respondents were eliminated from the analysis because they had minimal effects from their injuries and did not need prolonged standing as an extra activity. Of the 126 remaining respondents, 38 respondents (30%) reported that they engaged in prolonged standing for an average of 40 minutes per session, 3 to 4 times a week, as a method to improve or maintain their health. The perceived benefits included improvements in several health-related areas such as well-being, circulation, skin integrity, reflex activity, bowel and bladder function, digestion, sleep, pain, and fatigue. The most common reason that prevented the respondents from standing was the cost of equipment to enable standing. DISCUSSION AND CONCLUSION: Considering the many reported benefits of standing, this activity may be useful for people with SCI. This study identified a number of body systems and functions that may need to be investigated if clinical trials of prolonged standing in people with SCI are undertaken.

Posted on Leave a comment

Indications for a home standing program for individuals with spinal cord injury.

date: 09/01/1999
author: Walter JS, Sola PG, Sacks J, Lucero Y, Langbein E, Weaver F.
publication: J Spinal Cord Med. 1999 Fall;22(3):152-8.
pubmed_ID: 10685379

Additional analyses were conducted on a recently published survey of persons with spinal cord injury (SCI) who used standing mobility devices. Frequency and duration of standing were examined in relation to outcomes using chi square analyses. Respondents (n = 99) who stood 30 minutes or more per day had significantly improved quality of life, fewer bed sores, fewer bladder infections, improved bowel regularity, and improved ability to straighten their legs compared with those who stood less time. Compliance with regular home standing (at least once per week) was high (74%). The data also suggest that individuals with SCI could benefit from standing even if they were to begin several years after injury. The observation of patient benefits and high compliance rates suggest that mobile standing devices should be more strongly considered as a major intervention for relief from secondary medical complications and improvement in overall quality of life of individuals with SCI.

Posted on Leave a comment

Follow-up assessment of standing mobility device users.

date: 10/01/1998
author: Dunn RB, Walter JS, Lucero Y, Weaver F, Langbein E, Fehr L, Johnson P, Riedy L.
publication: Assistive Technology. 1998;10(2):84-93.
pubmed_ID: 10339284

The use of standing devices by spinal cord-injured subjects was investigated through a national survey of a sample of individuals who returned their manufacturer’s warranty card to two companies. We obtained a 32% response rate (99/310). The majority of respondents were male (87%) with a median age between 41 and 50 years. Seventy-seven percent were paraplegic and 21% were quadriplegic. Forty percent had between 1 and 5 years experience with their device, and 84% of those responding were currently using their standing device. Forty-one percent used their standing device one to six times a week; two-thirds stood between 30 minutes and 1 hour for each use. Less than 10% of subjects experienced any side effects, such as nausea or headaches, from standing. Twenty-one percent of subjects reported being able to empty their bladder more completely. There was also a favorable response by some individuals on the effects of the standing devices on bowel regularity, reduction of urinary tract infections, leg spasticity, and number of bedsores. Finally, 79% of subjects highly recommended use of standing devices to other people with spinal cord injury. The positive responses of individuals using standing devices is a strong recommendation for the assistive technology community to make these devices more available to individuals with spinal cord injury.